Thermal Shock Test Chamber with high precision perfect external design, external with double sides cold rolled plate electrostatic powder coated material, internal with SUS#304 high temperature resistant stainless steel. Insulation material adopt fire resistant high strength PU polyurethane foaming thermal insulating material. More than 20% energy saving is achieved thanks to the introducing of Japan & German advanced refrigerator control technology. Control system and control circuit components all with famous brand .
Specifications:
|
System |
Two-zone test by means of damper switching |
|||||||
|
Three-zone chamber |
||||||||
|
Model |
UP-6118 |
Customized |
||||||
|
Performance |
Test area |
High temp. exposure range*1 |
+60~ to +200°C |
|||||
|
Low temp. exposure range*1 |
-65 to 0 °C |
|||||||
|
Temp. fluctuation *2 |
±1.8°C |
|||||||
|
Hot chamber |
Pre-heat upper limit |
+200°C |
||||||
|
Temp. heat up time*3 |
Ambient temp. to +200°C within 30min |
|||||||
|
Cold chamber |
Pre-cool lower limit |
-65°C |
||||||
|
Temp. pull down time*3 |
Ambient temp. to -65°C within 70min |
|||||||
|
Temp. recovery (2-zone) |
Recovery conditions |
Two-zone: High temp. exposure +125°C 30 min, Low temp. exposure -40°C 30 min; Specimen 6.5 kg (specimen basket 1.5kg) |
||||||
|
Temp. recovery time |
Within 10 min. |
|||||||
|
Construction |
External material |
Cold-rolled rust-proofed steel plate |
||||||
|
Test area material |
SUS304 stainless steel |
|||||||
|
Door*4 |
Manually operated door with unlock button |
|||||||
|
Heater |
Strip wire heater |
|||||||
|
Refrigeration unit |
System*5 |
Mechanical cascade refrigeration system |
||||||
|
Compressor |
Hermetically sealed scroll compressor |
|||||||
|
Expansion mechanism |
Electronic expansion valve |
|||||||
|
Refrigerant |
High temp side:R404A, Low temp side R23 |
|||||||
|
Cooler |
Stainless steel welded plate heat exchanger |
|||||||
|
Air circulator |
Sirocco fan |
|||||||
|
Damper driving unit |
Air cylinder |
|||||||
|
Fittings |
Cable port with diameter 100mm on the left side (right side and tailor made diameter size are available as options), specimen power supply control terminal |
|||||||
|
Inside dimensions (W x H x D) |
350 x 400 x 350 |
500 x 450 x 450 |
Customized |
|||||
|
Test area capacity |
50L |
100L |
Customized |
|||||
|
Test area load |
5 kg |
10 kg |
Customized |
|||||
|
Outside dimensions (W x H x D) |
1230 x 1830 x 1270 |
1380 x 1980 x 1370 |
Customized |
|||||
|
Weight |
800kg |
1100kg |
N/A |
|||||
|
Utility requirements
|
Allowable ambient conditions |
+5~30°C |
||||||
|
Power supply |
AC380V, 50/60Hz, three phase , 30A |
|||||||
|
Cooling water supply pressure*6 |
02~0.4Mpa |
|||||||
|
Cooling water supply rate*6 |
8m³ /h |
|||||||
|
Operating cooling water temp. range |
+18 to 23 °C |
|||||||
|
Noise Level |
70 dB or lower |
|||||||
Meets International standards
Improved temperature uniformity performance
Reduced test time by means of test area transfer
Specimen Temperature Trigger (STT) function
Utility:
Boast of a 100L capacity
Smooth specimen transfer
Test area anti-drop mechanism to protect specimens
Safe specimen handling thanks to ambient temperature recovery
Easy wiring access
Viewing window (option)
Comprehensive safety system
Safety Devices:
Hot chamber overheat protection switch
Cold chamber overheat protection switch
Air circulator overload alarm
Refrigerator high/low pressure protector
Compressor temperature switch
Air pressure switch
Fuse
Water suspension relay ( water-cooled specification only)
Compressor circuit breaker
Heater circuit breaker
Test area overheat/overcool protector
Air purge valve
Control :
Operation and settings simplified by the use of a touch-screen LCD display (instructions displayed on-screen). At-aglance confirmation of test patterns, test area temperatures, temperature cycles, and trend graph displays.
|
Setting |
Interactive key input by touch panel |
|
Display |
LCD (5.7 inches) |
|
Temperature control function |
Test area: exposure temp. Hot chamber: pre-heating temp. Cold chamber: pre-cooling temp. |
|
PID control |
|
|
Preset temperature range |
High temperature: 60 to200'C Low temperature: -78 to 0'C |
|
Setting resolution |
1'C |
|
Input |
Thermocouple type T (Copper/Copper-Nickel) |
|
Setting and indication ranges |
Preset time: 0 min. to 99 hours and 59 min. Preset cycle: 1 to 9,999 cycles |
|
Accessory function |