Customization: | Available |
---|---|
After-sales Service: | One Year Warranty, Lifetime Maintenance |
Power Supply: | 220V |
Suppliers with verified business licenses
Comply with international standards GB/T 28046.4-2011 (ISO 16750-4: 2006): Environmental conditions and tests of road vehicle electrical and electronic equipment --- Part 4 --- climate load, VW80000: 2009-10 LV124 3.5 tons below The requirements of automotive electrical and electronic component test items, test conditions and test requirements. |
1. It is suitable for the ice -resistant spatter test of the product, and the ice water immersion test. 2. The shell is processed by the domestic high -quality steel plate CNC machine tools, and the surface is sprayed with paint, which is beautiful and durable. 3. All inner boxes are made of SUS316#stainless steel plate to ensure that it is not rust for a long time. 4. Insulation material: high -density glass fiber cotton, ensure thermal insulation performance, maintain the indoor balance and stable temperature. 5. There is a transparent observation window (multi -layer hollow tempered glass) on the door. LED lighting lights are installed on the door to facilitate the internal testing situation 6. The high -temperature system uses a long -axis fan motor, which is resistant to high and low temperature 316 stainless steel multi -wing leaf wheels to achieve the intensity -to -vertical diffusion cycle, so that the temperature in the laboratory is uniform and stable; 7. Between the door of the device and the box, the double -layer high -temperature high -temperature sealing strip is used to ensure the confinement of the test area. Made of the material inner plate materials is made of 316 stainless steel, and it is easier to operate with a coupleless door handle; 8. Test holes (100mm in diameter) are installed on the left side of the device, which can be used to test the power cord or signal line to use; 9. The design of the equipment control part is designed on the right side of the device. It has a control touch screen, control switch, etc., which is convenient and easy to maintain; 10. Install high -quality fixed PU activity Korean foot wheels at the bottom of the machine, which can easily move the machine to the specified position, and finally fix the foot wheel; 11. The control system adopts a 7 -inch touch screen+Panasonic PLC. Electric components use imported brands such as LS and Omron. The wiring process meets the requirements of national standards. The electrical plate layout is reasonable, the wiring is firm, and the indication is clear. 12. Use 7 -inch LCD touch screen control+PLC control can control the temperature, water tank temperature, flow and water pumps and testing time in the box; traffic and temperature are directly displayed on the touch screen, automatic constant current and constant temperature. 13. The refrigeration system of the equipment is installed at the bottom, and the compressor adopts the French Taikang brand to ensure the refrigeration effect and reliability. 14. The refrigeration system adopts a fully closed French Taikang compressor. The condensation method is air -cooled, and the R404R environmentally friendly refrigerant is used. The full system pipeline passes the 48h leak testing test to confirm that the refrigeration system can run stable for a long time. 15. Ice water splash test: The spraying peak is fixed on the right side of the test box; the water spray distance is adjusted through the sample movement 16. Slim-gap spraying (316L material, disassembly and cleaning, as shown in the following figure) 1, satisfy GB/T28046.4-2011: 5.4 Ice water impact test: Figure 4, strictly designed and manufactured according to standards: 17. Flow sensor: The flow sensor is used to control the flow of the ice water splash test. The signal of the flow sensor will be fed back to the PLC. The automatic constant current is controlled by PID, and the flow is displayed directly on the touch screen. 18. Ice water immersion test: This test is performed when the test is different from the splash test to meet the 5.4.3 provisions of GB/T28046.4-2011. , Soaking without time, the setting range is 1 to 5min, the number of loop settings: 1 to 999 times, the temperature recovery time in the water tank is 30min; 19. Set automatic high and low water level in the water tank. The high water level is used to do ice water immersion tests. The bottom water level is used to do ice water splash test to reduce the amount of dust use; 20. The ice water splash test and the water tank flushing circulation test uses a custom cycle pump to ensure the stable flow and water temperature. 21. The ice water temperature control device adopts water circulation refrigeration method to ensure the uniformity of water temperature and mixed water. 22. The equipment has the function of automatic cleaning the pipeline and the inner box. |
Structure parameter | |
High -temperature internal box size: | About 1000*deep 1000*height 1000mm. |
External dimensions: | About 1600*deep 1950*high 2710mm. |
Basket size: | About 500*deep 500*500mm. |
Immerse water tank size: | About 600*depth 600*600mm. |
Number of spray holes: | 1 sewing spray torion; |
Spray hole position: | On the right side of the inner box. |
The distance between the nozzle and the sample: | 325 ± 25mm (manual adjustment). |
Lan Lan load: | 50kg. |
Immersed water tank: | About 200L (stirring in circulating water, the bottom slope, easy to clean and drain). |
Function parameter | |
High temperature room temperature range: | RT+10 ºC ~ 150 ºC (touch screen setting). |
Heating rate: | RT+10 ºC ~ 150 ºC ≤45min. |
Water temperature control range: | (0 ~+4) ºC (touch screen setting). |
Cooling rate: | 25 ºC ~ 2 ºC ≤60min. |
Water spray flow: | (3 ~ 4) L/3s (touch screen setting). |
Test liquid medium: | Deionized water. |
Spit time (30min) every cycle (30 minutes): | 3s, interval time: interval time: 29m57s (touch screen setting). |
Number of cycles: | 100 times (touch screen setting). |
Tim Lan Rate Time: | ≤20s (touch screen setting). |
Every time I immerse it: | 1 ~ 99 min (touch screen setting). |
Number of immersion: | 1 ~ 99 (touch screen setting). |
The temperature uniformity of the ice water in the box of the box: | ± 0.5 ºC. |
Automatic cleaning function: | After the test is completed, automatically clean the pipelines and inner boxes (need to match the spray gun). |
Water temperature cooling method: | Pipe circulation water flow to cool down. |
Dust hybrid method: | Pipe circulation water flow mix. |
Spray water nozzle: | Folding the crack nozzle (the nozzle can be disassembled and cleaned). |
How to use the test liquid: | Circular use. |
Sample carrier table: | Can be lifted. |
Standards compliant: | ISO16750-4,GB/T 28046.4-2011,VW80000 |
Electrical parameter | |
Equipment power supply: | 380V/50Hz,3-phase 5-wire |
equipment power: | 15.0KW |
Safety protection function: | Leakage protection, water deficiency protection, short -circuit protection, phase sequence protection, heat overload protection. |